Problems needing attention in the process of electric gynecological bed
- Categories:Industry News
- Author:
- Origin:
- Time of issue:2022-11-23 16:19
- Views:
(Summary description)Issues that need attention in the process of using electric gynecological bed:(1) Press the electric grab switch on the panel of the hand press controller to enter the operation preparation stage.
Problems needing attention in the process of electric gynecological bed
(Summary description)Issues that need attention in the process of using electric gynecological bed:(1) Press the electric grab switch on the panel of the hand press controller to enter the operation preparation stage.
- Categories:Industry News
- Author:
- Origin:
- Time of issue:2022-11-23 16:19
- Views:
Issues that need attention in the process of using electric gynecological bed:
(1) Press the electric grab switch on the panel of the hand press controller to enter the operation preparation stage.
(2) Start and release the base brake correctly. Step down the brake auxiliary plate next to the base, and move it under the fixed rod to fix it. Start the central mechanical brake assembly to fix the operating table.
(3) Prevent external injuries
1. Prevent tipping: The electric gynecological bed is not locked and fixed after the base brake is turned on. At this time, the electric gynecological bed may be shifted and tilted when the operating table is operated or the patient is moved. For example, the patient falls off the bed. So be sure to lock the electric gynecological bed after completing the adjustment operation.
2. Prevent pinching or crushing: Do not put your feet under the base when releasing the base brake.
3. Prevent tripping: put the wires in an appropriate position to avoid tripping when walking.
4. To prevent electric shock: Do not operate or maintain the operating table when the electrical inspection cover or control components are removed.
5. Prevention of burns: When using the electric knife, prevent the patient's skin from touching the metal parts of the electric gynecological bed to avoid bypass burns.
(4) The hand-pressed control panel should be hung on the side rails of the electric gynecological bed. The circuit should avoid surface pinching and crushing to prevent the circuit from being damaged.
Scan the QR code to read on your phone
Online Message
If you are interested in us, welcome your message, we will reply you in time!
Hotline:
Outlook : Ervinao@outlook.com
Foreign trade mailbox: sales5@chinajianghai.com
Address: No.68, South District, Shigang Industrial Park,
Tongzhou District, Nantong City, Jiangsu Province
Folllow us

Mobile Website
Copyright © 2020 NANTONG MEDICAL APPARATUS CO.,LTD. All Right Reserved. 苏ICP备20010639号 Powered by:www.300.cn